Air Quality VOC/CO2+T sensor BIO 2000 ROOM

Demand controlled ventilation with BIO sensors iAQ technology means maintaining excellent indoor air quality and occupants’ health at minimum cost.

Description

The room air quality VOC/CO2+T sensor BIO 2000 ROOM is a low-cost, high-quality and low-maintenance VOC (Volatile Organic Compounds) and CO2 (Carbon Dioxide) sensor based on modern bio-semi-conductor technology.
The BIO 2000 ROOM also measure Temperature.

The room air quality sensor detects VOC/CO2 and Temperature contents in air and emits proportional, linear, two analog outputs and digital RS-485 ModBus signal.

The normal CO2 values are not causing any problems in closed areas but different substances like VOC/CO2 can be responsible for symptoms like eye irritations, headaches, feebleness, dizziness, as well as diseases and accordingly overexertion like sick building syndrome.

Beyond measurement of CO2 concentration the VOC/CO2 sensor detects the air quality similar to human sensation. That’s why VOC/CO2 measurement is the perfect method to define air quality.

Features

  • VOC/CO2 Sensor type
  • Bio-sensor-conductor

  • Measurement ranges
  • VOC/CO2 = 0-2000 ppm (on request 0-4000 ppm)
    Temperature = 0 to +30°C

  • Analog output signals
  • VOC/CO2 = 0-10 Vdc
    Temperature = 0-10 Vdc

  • Accuracy
  • VOC/CO2 = ± 150 ppm
    Temperature = ± 0.5°C

  • Serial interface Modbus RS-485
  • Power supply 24 Vac/dc
  • Internal automatic self-diagnostics with auto adjustment
  • High accuracy, selectivity and reliability
  • Automatic drift and temperature compensation
  • Good resistance to poisoning
  • Life expectancy > 10 years
  • Maintenance interval > 5 years

Ventilation Energy Savings
While Maintaining Premium Air Quality


Intelligent air quality

Adults consume two to three liters of liquids and one to two kilograms of food per day. While hygiene and safety of edibles receive great attention, air quality gets very little even though on average we inhale 15 kg of air per day — 80% of which indoors.

From the classroom to the cubicle, the benefits of maintaining good indoor air quality extend beyond protecting the occupants’ health.

Students in schools with healthy air are more proficient at retaining information and teachers have fewer sick days.

For employers, studies show that improving indoor air quality directly correlates with higher productivity and a more satisfied workforce.

Moreover, the advent of “green buildings” and emission-dependent energy taxes has created awareness for both indoor air quality and ventilation energy costs.

Consequently, in modern or reconstructed buildings, the alternatives of either having minimal ventilation with poor air quality on the one hand or permanent ventilation with high ventilation energy costs on the other are impractical.

A balance between the two extremes exists in “Demand Controlled Ventilation” or DCV. This paper is focused on air quality sensors for DCV. It describes typical indoor air contaminants, their sources, and their impact on human health.

Moreover, it confronts current indoor air quality standards with modern ventilation demands and compares today’s commercially available air quality sensor technologies accordingly.

Finally, suggestions for improvement of typical ventilation scenarios by using BIO intelligent air quality solutions are provided.

Anatomy of Indoor Air

Clean air is comprised of 21% oxygen, 78% nitrogen and 1% argon.

However, indoor environments are different where other noble gases, carbon monoxide (CO), carbon dioxide (CO2) and volatile organic compounds (VOCs), also known as mixed gas, exist with different prominence.

When it comes to the impact on health the latter two are the most important ones: CO2 for its HVAC (Heat, Ventilation, and Air Conditioning) industry awareness, and VOCs for their criticality.


…beyond CO2

The Role and Impact of VOCs in Indoor Air

There are estimated to be 5,000 to 10,000 different VOCs, which are two to five times more likely to be found indoors than outdoors. Indoor VOCs are hydrocarbons that originate from two primary sources: bio-effluents, that include odors from human respiration, transpiration and metabolism; and vapors generated from building materials and furnishings.

VOCs cause eye irritations, headache, drowsiness or dizziness, and contribute to a condition known as “sick building syndrome” or SBS, whereby adequate ventilation must be provided.

Aside from industrial conditions and comfort aspects such as temperature control, VOCs are the most critical reason to ventilate.

Some typical indoor contaminants and their sources are shown in Table 1. Clearly, humans represent the greatest source of VOCs, directly and indirectly; far beyond building materials, furniture and office equipment, and thereby dominate the demand for ventilation.


The Role and Impact of CO2 in Indoor Air

Although CO2 is listed twice in Table 1 and plays a major role in modern ventilation control, it has no permanent effect on humans, especially in small doses.

Exposures on submarines and the International Space Station confirm that even heavy CO2 concentrations of 1% (10,000ppm) show no irreversible impact on occupant well-being.

Due to the lack of suitable VOC sensing devices, CO2 has served historically as an adequate air quality indicator.

Moreover, since the amount of CO2 is proportional to the amount of VOCs produced by human respiration and transpiration (Metabolic Rule) CO2 levels reflect the total amount of VOCs (TVOCs) as illustrated in Diagram 1.


The Volatility of Volatile Organic Compounds

Diagram 1 illustrates more than just the correlation between VOCs and CO2. Importantly, the diagram also demonstrates that VOCs are much more volatile, or sudden in their occurrence.

An increase of human bio-effluents or the intermittent use of odorous materials such as cleaning supplies, perfumes or cigarette smoke is not uncommon.

Diagram 1 shows spikes of these events; thus, relying exclusively on CO2 as a ventilation reference will lead to unsatisfactory results.

Ventilation should react on demand toward all contamination sources, not only CO2. This points out the weakness of CO2 - based DCV. Detecting a broader range of contaminants optimizes ventilation energy savings and minimizes the impact on human occupants.


Indoor Air Quality References From Past to Present

Historically, CO2 has been the detection gas of choice since it is a reasonable reference and its detection is fairly easy.

Mixed gas or VOC detectors suffered early criticism due to long-term stability problems and the inability to calibrate output units.

Further, without suitable threshold values, HVAC planners using VOC detectors could not easily set ventilation rates and VOC sensor drift made the entire ventilation system functionally unpredictable. Although the motivation to measure the root cause for contaminated air was appropriate, the implementation was not successful.


BIO Sensor Approach — Close to Human Perception

Taking into account the lack of VOC standards, BIO sensors iAQ, intelligent Air Quality, sensor takes advantage of its Reversed Metabolic Rule technology, RMR.

RMR technology calibrates measured VOC concentrations to CO2 - equivalent ppm-values, thereby achieving full compatibility to CO2 - standards.

Moreover, the iAQ sensor captures all VOC odor emissions that are completely invisible to CO2 sensors as Diagram 2 demonstrates.

Importantly, BIO sensor control algorithms correct for sensor drift and aging and thereby provide consistency.

The iAQ sensor overcomes deficiencies of CO2 measurement by detecting the true root-cause of ventilation demand, VOCs.

Further, the iAQ sensor remedies deficiencies of typical VOC sensing technologies by signal-adherence to established CO2 standards and stringent drift compensation for extended sensor life.

The iAQ sensor emulates the human perception of air quality and even detects odorless, potentially hazardous substances such as carbon monoxide.

Diagram 2 – Typical scenarios where CO2 sensors fail as DCV reference


Which Reference to Follow

Today, various types of DCV sensors are available including occupation detection, CO2 detection, humidity measurement and VOC sensing. Table 3 compares the performance of the latter three air quality sensor technologies over various applications, clearly depicting the advantage of BIO sensor ’s intelligent Air Quality technology.


When and How to Ventilate

The answer is: on demand. Most VOC events are unpredictable as they are dominated by human metabolism and behavior, which accounts for more than 85% of all ventilation cases.

The remainder comes from building material emissions common in new buildings and after refurbishments or from furnishings and coatings.

To dilute these emissions sufficiently, low-rate, permanent ventilation at 5-10% of maximum is adequate.

Table 1 lists relevant substances and recommended ventilation scenarios.

VOC emissions rarely occur in isolation; therefore, a combination of both ventilation types is the ideal solution.


What to Save By DCV

There are many options to achieve energy savings in ventilation.

Ventilation systems can be operated permanently with constant air volume, CAV, statistically with variable air volume, VAV, and on-demand, DCV.

DCV, however, has many control options to choose from: occupation, CO2, VOC, and humidity are today’s typical reference variables in use.

Tests conducted at a fitness center comparing the iAQ sensor against timer-controlled ventilation installed in an air handling unit showed 24% less operating time, which translates to a 60% energy cost savings.

Visitors to the fitness center gave the air quality improved ratings.


Download Datasheet

Data sheet room air quality VOC/CO2+T sensor BIO 2000 ROOM.pdf


Download Manual with Modbus Protocol

Manual room air quality VOC/CO2+T sensor BIO 2000 ROOM with Modbus Protocol.pdf


Download Declaration of Conformity

Declaration of Conformity VOC/CO2 sensor BIO 2000-series.pdf


Options

  • Potentiometer
  • Passive temperature sensor OEM
  • 1 digital input
  • 2 digital inputs
  • 1 digital output
  • 2 digital outputs
  • 3-stage switch
  • 1 LED
  • 2 LED´s
  • BACNet

All options are not possible in combination, ask VCP for more details when any of above option(s) required.


Feel free to contact us if you're intressted in the product or have any questions.

Or write us an e-mail in the contact form below straight away.










(Leave empty)