VOC = Volatile Organic Compounds
Room Air Quality (VOC) transmitter VOCR 51 MDR2B
Room Air Quality (VOC) transmitter VOCR 51
Description
Room Air Quality (VOC) transmitter VOCR-series
The Room Air Quality (VOC) transmitter VOCR-series have
MEMS type MOX sensing element
Output(s) for Room Air Quality (VOC) transmitter VOCR-series are
0-10 Vdc, 2-10 Vdc, 4-20 ma, 0-5 Vdc or 1-5 Vdc
(One output and Two VOC outputs available).
Estimated operating life for
Room Air Quality (VOC) transmitter VOCR-series is
minimum 5 years.
Accuracy for Room Air Quality (VOC) transmitter VOCR-series is +/-10% FSO.
Power supply for Room Air Quality (VOC) transmitter VOCR-series is 24 Vac/dc.
"Options"
- Modbus RS485
- LCD Display
- 1 x relay output , can be set individually
- 2 x relay outputs , can be set individually
- Buzzer
VOC Ranges/Sensitivity
0V or 4mA: BEST, Clean Air
1V or 5.6mA: STANDARD, calibrated level, reference level
10V or 20mA: WORST, polluted air
In normal conditions, base level is equals to 1V.
Lower than 1V is better than calibrated situation.
In some cases, indoor condition may be better than calibrated level.
Higher than 1V is showing polluted air level.
Pollution is measured from 1V to 10V.
Sensitivity for VOC.
Higher response for VOC gasses at HIGH sensitivity.
10V of HIGH is equal to 4V of LOW.
10V of MEDIUM is equal to 6V of LOW.
1V is same for all sensitivities.
Example: 3.0V @ LOW == 4.6V @ MEDIUM == 7.0V @ HIGH
Detectable gases
• Cigarette smoke
• Automobile exhaust
• Breath air
• Carbon monoxide (CO)
• Solvent fumes• Alcohol fumes
• Acetone
• Acrylonitrile
• Ammonia
• Benzene
• Chlorine
• Dimethyl amine
• Ethane
• Ethanol
• Ethylene
• Ethylene oxide
• Formaldehyde
• Hydrogen
• Hydrogen sulfide
• Isobutane
• Methane
• Methanol
• n-Hexane 2
• n-Petane
• Propane
• Sulfur dioxide
Ordering examples
VOCR 51
Room Air Quality (VOC) transmitter
VOC output 1: 4-20 mA
VOC output 2: 0-10 Vdc
VOCR 51 M
Room Air Quality (VOC) transmitter
VOC output 1: 4-20 mA
VOC output 2: 0-10 Vdc
Modbus RS485 communication
VOCR 51 MDR2B
Room Air Quality (VOC) transmitter
VOC output 1: 4-20 mA
VOC output 2: 0-10 Vdc
Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer.
See data sheet for wide range of different combinations.
Download datasheet
Data Sheet
Room Air Quality (VOC) transmitter VOCR-series.pdf
Download CE declaration of conformity
CE declaration of conformity
Room Air Quality (VOC) transmitter VOCR-series.pdf
Contact us
Feel free to contact us if you're intressted in the product or have any questions.
Or write us an e-mail in the contact form below straight away.