Duct Carbon Dioxide (CO2) transmitter CO2D 51 MDR2B
with extra 100 mm lenght
duct probe EDP 100
Duct Carbon Dioxide (CO2) transmitter CO2D 51
with extra 100 mm lenght
duct probe EDP 100
Description
Duct Carbon Dioxide (CO2) transmitter CO2D-series
Duct Carbon Dioxide (CO2) transmitter CO2D-series have a
maintenance free NDIR sensor
Measuring ranges for duct Carbon Dioxide (CO2) transmitter CO2D-series are
400-2.000 ppm, 0-2.000 ppm, 0-5.000 ppm, 0-10.000 ppm
selectable ranges with DIP switch
On request 0-1.000 ppm.
Output(s) for duct Carbon Dioxide (CO2) transmitter CO2D-series are
0-10 Vdc, 2-10 Vdc, 4-20 ma, 0-5 Vdc or 1-5 Vdc
(One output and Two CO2 outputs available).
Estimated operating life for duct Carbon Dioxide (CO2) transmitter
CO2D-series is 15 years.
The duct Carbon Dioxide (CO2) transmitter CO2D-series have
ABC – Automatic Baseline Calculation.
Accuracy for duct Carbon Dioxide (CO2) transmitter CO2D-series is
70 ppm +3 % reading.
Power supply for duct Carbon Dioxide (CO2) transmitter CO2D-series is 24 Vac/dc.
"Options"
- Modbus RS485
- LCD Display
- 1 x relay output , can be set individually
- 2 x relay outputs , can be set individually
- Buzzer
Temperature and Humidity Options
- Temperature measuring ranges 0 to +50°C or -30 to +70°C
- Temperature output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc
- Humidity measuring ranges 0 to 100% rH
- Humidity output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc
Ordering examples
CO2D 51
Duct Carbon Dioxide (CO2) room transmitter
Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
CO2D 51 M
Duct Carbon Dioxide (CO2) room transmitter
Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
Modbus RS485 communication
CO2D 51 MDR2B
Duct Carbon Dioxide (CO2) room transmitter
Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer
CO2D C1T1H1 MDR2B
Carbon Dioxide (CO2) duct transmitter with Temperature and Humidity options
CO2 output 0-10 Vdc
TEMP. output 0-10 Vdc
HUM. output 0-10 Vdc
Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer
See data sheet for wide range of different combinations.
EDP 100
Extra Duct Probe, length 100 mm x diameter 30 mm
Standard duct probe length is 100 mm.
Duct probe length can be extended to 200 mm with EDP 100
(100 mm + 100 mm = 200 mm)
Download datasheet
Data Sheet duct Carbon Dioxide (CO2) CO2D-series.pdf
Download CE declaration of conformity
CE declaration of conformity duct Carbon Dioxide (CO2) CO2D-series.pdf
Contact us
Feel free to contact us if you're intressted in the product or have any questions.
Or write us an e-mail in the contact form below straight away.