Refrigerant-Freon Gas Detector IHFC

refrigerants-gas-detectors-ihfc

Refrigerant-Freon Gas Detector IHFC


Description Refrigerant-Freon Gas Detector IHFC

Refrigerants Gas Detectors IHFC-series to be used in HVAC / BMS Systems • Examples: hotels, residential, hospitals, offices and apartment blocks.


Key Features

Accurate Gas Detection

• Metal oxide gas sensing element

• Detection range: 0–1000 ppm
On request 0-2500 ppm

• Long-lasting sensor with 5+ years lifetime

Outputs

• Dual analog outputs: 2 x 4–20 mA or 2 x 0–10 Vdc (user-selectable)

• RS485 interface with Modbus RTU protocol

Smart Alarms & Control

2 x SPST relays / 2 configurable alarm setpoints:

• Alarm 1: 250 ppm

• Alarm 2: 500 ppm

• Integrated 85 dB buzzer for local alerts

Power Supply

• Standard: 24 Vdc (11–30 Vdc)

• Optional: 24 Vac or 230 Vac


Why Choose This Detector?

• Improves safety by detecting refrigerant leaks early

• Easily integrates with building management systems

• Reduces maintenance with long sensor life

• Supports automation with Analogue outputs, Modbus control and Relay Outputs


Ordering

IHFC R410A
Refrigerant Gas Detector R-410a
0-1000 ppm, 24 Vdc

IHFC R134A
Refrigerant Gas Detector R-134a
0-1000 ppm, 24 Vdc

IHFC R123
Refrigerant Gas Detector R-123
0-1000 ppm, 24 Vdc

IHFC R404A
Refrigerant Gas Detector R404a
0-1000 ppm, 24 Vdc

IHFC R12
Refrigerant Gas Detector R-12
0-1000 ppm, 24 Vdc

IHFC R125
Refrigerant Gas Detector R-125
0-1000 ppm, 24 Vdc

IHFC R143
Refrigerant Gas Detector R-143
0-1000 ppm, 24 Vdc

IHFC R22
Refrigerant Gas Detector R-22
0-1000 ppm, 24 Vdc

IHFC R407C
Refrigerant Gas Detector R-407c
0-1000 ppm, 24 Vdc

IHFC R1233ZD
Refrigerant Gas Detector R1233ZD
0-1000 ppm, 24 Vdc

24VAC
Option for 24 Vac supply

230VAC
Option for 230 Vac supply

Refrigerants Gas Key Characteristics

Colorless:
Refrigerants do not have a visible color when released as a gas, making leaks hard to detect visually.

Odorless:
Most refrigerants (such as R-134a, R-410A, R-22, R-404A, etc.) have no natural smell, so they typically cannot be detected by scent alone.

Without proper detection, refrigerant gases can pose serious health hazards, including life-threatening asphyxiation.
Mounting Positions of Refrigerants Gas Detectors

Examples:

R-134a, R-22, R-404A, R-410A, R-407C

Mounting height:
15–50 cm above the floor

Why:
These refrigerants are denser than air and tend to accumulate near the ground.

Standard coverage:
20 to 50 m² per detector
In larger, well-ventilated spaces:
up to 80 m² may be possible with ideal airflow and proper placement

Additional Considerations: Place near potential leak sources

Download datasheet

Data Sheet Refrigerants Gas Detectors IHFC.pdf


Download CE declaration of conformity

CE declaration of conformity Refrigerants Gas Detectors IHFC.pdf


Contact us

Feel free to contact us if you're intressted in the product or have any questions.

Or write us an e-mail in the contact form below straight away.










(Leave empty)